Technical Data | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
TYPE
|
H
|
tbl
|
H1
|
Ød/DE
|
L
|
m
|
h
|
|||
m
|
mm
|
m
|
mm
|
mm
|
kg
|
m
|
||||
S-60SRwPG/Ø70
|
6,0
|
4
|
2,1
|
60/140
|
100
|
73,0
|
1,2
|
|||
S-70SRwPG/Ø70
|
7,0
|
4
|
2,1
|
60/140
|
100
|
87,0
|
1,2
|
|||
S-80SRwPG/Ø70
|
8,0
|
4
|
2,1
|
60/170
|
100
|
107,0
|
1,2
|
|||
S-90SRwPG/Ø70
|
9,0
|
4
|
2,1
|
60/170
|
100
|
119,0
|
1,5
|
|||
S-100SRwPG/Ø70
|
10,0
|
4
|
2,1
|
60/170
|
100
|
123,0
|
1,5
|
|||
S-110SRwPG/Ø70
|
11,0
|
4
|
2,1
|
60/170
|
100
|
143,0
|
1,7
|
|||
S-120SRwPG/Ø70
|
12,0
|
4
|
2,1
|
60/170
|
100
|
149,0
|
1,7
|
Depth “h” of embedding in soil calculated for native soil (with intact structure) and geotechnical parameters from group II
Note: H1 – the reduction for of street pole is ordered as separate element
Number of reductions depend on the type of street poles
Ød – other mounting diameters must be specified in the inquiry or order
Strength data
|
||||||
TYPE
|
Masa Opraw
|
Wind zone acc, to PN EN 1991-1-4 |
MF
|
|||
kg
|
I ≤300m a.s.l. |
I ≤500m a.s.l. |
II ≤300m a.s.l. |
III ≤950m a.s.l. |
kNm | |
50 | 1,479 | 1,093 | 0,995 | 0,702 | 9,0 | |
50 | 1,042 | 0,745 | 0,671 | 0,453 | 9,0 | |
50 | 1,518 | 1,128 | 1,024 | 0,716 | 14,2 | |
50 | 1,163 | 0,830 | 0,746 | 0,503 | 14,2 | |
50 | 0,818 | 0,589 | 0,520 | 0,326 | 14,2 | |
50 | 0,614 | 0,394 | 0,339 | 0,189 | 14,2 | |
50 | 0,424 | 0,241 | 0,194 | 0,073 | 14,2 |