1  

Technical Data
TYPE
H
hd
Ød1
Ød/DE
h1
h2
h3
m
h
 
m
mm
mm
mm
m
m
m
kg
m
S-60SRsPG
6,0
400
89
60/114
2,2
2,0
3,0
50,4
1,2
S-70SRsPG
7,0
400
89
60/114
2,2
2,0
4,0
54,9
1,2
S-80SRsPG
8,0
600
89
60/133
2,5
3,0
3,7
71,3
1,2
S-90SRsPG
9,0
600
89
60/140
3,0
4,0
3,5
86,3
1,5
S-100SRsPG
10,0
600
89
60/159
3,5
4,0
4,0
102,0
1,5

Depth “h” of embedding in soil calculated for native soil (with intact structure) and geotechnical parameters from group II
Ød – other mounting diameters must be specified in the inquiry or order

Strength data
TYPE
Weight of iluminaires

Wind zone acc, to PN EN 1991-1-4
Permissible surface of luminaires [m2]

MF
 
kg

I≤300m

a.s.l.

 

I≤500m

a.s.l.

II≤300m

a.s.l.

III≤950m

a.s.l.

kNm
40 0,629 0,441 0,393 0,250 4,7
40 0,400 0,258 0,221 0,113 4,7
40 0,448 0,318 0,285 0,182 6,4
40 0,410 0,255 0,217 0,104 7,7
35 0,329 0,190 0,156 0,053 8,3

Downloadable:
Ikony- pdf Straight welded tubular street lamp posts for in-soil installation – SRsPGCatalog page