1 2 3
Technical Data
TYPE
H
hopr
hpan
Ød/DE
Ød1
Ød2
Ødt
W
m
a x a x h
TYP
 
m
m
m
mm
mm
mm
m
m
kg
m
S-60SRwH
6,0
4,0
4,5
48;60/170
48
83
1,2
2,0
72,0
0,3 x 0,3 x 1,5
F150/200
S-70SRwH
7,0
5,0
5,5
48;60/196
48
114
1,2
2,0
91,0
0,3 x 0,3 x 1,5
F150/200
S-80SRwH
8,0
6,0
6,5
48;60/205
48
114
1,2
2,0
142,0
0,4 x 0,4 x 1,6
F160

Guidelines:

  • Maximum weight of the lamp holder 15 kg
  • The maximum surface of the lamp holder A = 0,15 m2
  • One-arm bracket Wmax = 2,5m
  • Batteries installed outside the column

Check all the main deviations from these guidelines with the producer before placing an order.

Strength data
TYPE
Weight of panels

Wind zone acc, to PN EN 1991-1-4
Permissible surface of luminaires [m²]

MF
 
kg

I≤300m a.s.l.

I≤500m a.s.l.

II≤300m a.s.l.

III≤950m a.s.l.

kNm
S-60SRwH 90 2,377 1,741 1,613 1,149 20,0
S-70SRwH 90 2,549 1,895 1,723 1,276 25,0
S-80SRwH 90 2,308 1,806 1,591 1,178 35,0

Downloadable:
Ikony- pdf  LIGHTING COLUMNS POWERED WITH RENEWABLE ENERGYCatalog page