Technical data | |||||
---|---|---|---|---|---|
TYPE
|
h
|
a
|
nxØs
|
m
|
Mg
|
m
|
m
|
mm
|
kg
|
kNm
|
|
F120PS-HE
|
1,2
|
0,43
|
3xM24
|
250
|
25,5
|
F150PS-HE
|
1,5
|
0,43
|
3xM24
|
320
|
31,2
|
Design:
The foundation is made of C16/20 class reinforced concrete with penetrations for routing electrical cables with a maximum cross-section of 4×95 mm2. The foundation is equipped with 3x M24 anchors for fixing the base of the column foot. Steel elements of the foundation: anchors, catches, bolts – all fasteners are galvanized.
Application:
The F120/PS-HE and F150/PS-HE foundations are intended for setting the new generation safety lighting poles.
The F120/PS-HE or F150/PS-HE foundation, together with the next generation safety poles listed below, ensure the HE energy absorption category for the entire pole-foundation structure (they stop the vehicle or slow it down significantly);
– steel poles t = 3mm; S-_PC-3PS series straight poles, height from 4 m to 11 m,
– steel poles t = 3mm; S-_C-3PS series poles with arms, height from 5 m to 12 m,
– steel poles t = 3mm; S-_PC-3PS-2w series straight poles, height from 4 m to 11 m,
– steel poles t = 3mm; S-_C-3PS-2w series poles with arms, height from 5 m to 12 m.
HE category structures – high energy absorption (stop the vehicle or slow it down significantly);
– recommended for zones of increased pedestrian and bicycle traffic and pedestrian crossings, where there is a risk of a secondary collision with other road users or pedestrians and obstacles within the built-up area as they can stop the vehicle or slow it down significantly at higher speeds, reducing the effects of secondary collisions.
Downloadable:
HE Class FOUNDATIONS for SAFETY LAMP POSTS – Catalog page