Technical Data | |||||||
---|---|---|---|---|---|---|---|
TYPE
|
W
|
H
|
H2
|
Ød/DE
|
Z
|
m*
|
a x a x h
TYPE |
m
|
m
|
m
|
mm
|
mm/m
|
kg
|
m
|
|
S-100C-PS
|
1,0
|
10
|
0,75
|
60/196
|
12
|
86
|
0,3 x 0,3 x 1,5
F150/200-PS |
1,5
|
87
|
||||||
2,0
|
89
|
||||||
2,5
|
91
|
||||||
S-110C-PS |
1,0
|
11
|
1,75
|
92
|
|||
1,5
|
93
|
||||||
2,0
|
94
|
||||||
2,5
|
95
|
||||||
S-120C-PS |
1,0
|
12
|
2,75
|
98
|
|||
1,5
|
99
|
||||||
2,0
|
100
|
||||||
2,5
|
101
|
* – Data for single arm brackets,
Ød, α° – other assembly diameters and inclination angles should be specified in the inquiry or order.
Passive safety classification according to PN-EN 12767:2019:
100HE-C-S-SE-SD-0; 70HE-C-S-SE-SD-0; 50HE-C-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100HE3; 70HE3; 50HE3;)
Strength data | |||||||
---|---|---|---|---|---|---|---|
TYPE
|
W
|
Weight of iluminaires
|
Wind Zone, PN EN 1991-1-4
Permissible surface of luminaires [m2] |
MF
|
|||
m
|
kg
|
I≤ 300m a.s.l. |
I≤ 500m a.s.l. |
II≤ 300m a.s.l. |
III≤ 950m a.s.l. |
kNm | |
Single arm bracket |
|||||||
S-100C-PS | 1,5 | 15 | 0,653 | 0,471 | 0,427 | 0,297 | 12,3 |
S-110C-PS | 1,5 | 15 | 0,485 | 0,334 | 0,297 | 0,190 | 12,3 |
S-120C-PS | 1,5 | 15 | 0,355 | 0,226 | 0,194 | 0,090 | 12,3 |
Two arm bracket | |||||||
S-100C-PS | 1,5 | 15 | 0,652 | 0,426 | 0,370 | 0,214 | 12,3 |
S-110C-PS | 1,5 | 15 | 0,456 | 0,268 | 0,222 | 0,100 | 12,3 |
S-120C-PS | 1,5 | 15 | 0,300 | 0,140 | 0,100 | – | 12,3 |
Downloadable: STEEL, ROUND SECTION, WITH ARM – “ST” ARM C-PS, HE–C CATEGORY – Catalog page