Technical data
TYPE
H
tbl
Ød/DE
Z
L
m
a x a x h TYPE
 
m
mm
mm/m
mm/m
mm
kg
m
S-90PCN-3PS
9,0
3,0
60/198
12,5
100
97
0,3 x 0,3 x 1,5
F150/200-PS
S-100PCN-3PS
10,0
3,0
60/198
12,5
100
102
0,3 x 0,3 x 1,5
F150/200-PS
S-110PCN-3PS
11,0
3,0
60/198
12,5
100
107
0,3 x 0,3 x 1,5
F150/200-PS

Ød – other mounting diameters should be specified in the inquiry or order.

Passive safety classification according to PN-EN 12767:2019: 100LE-E-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100LE1;)

Strength data
TYPE
Weight of iluminaires
Wind Zone, PN EN 1991-1-4
Permissible surface of luminaires [m2]
MF
 
kg
I≤300m
a.s.l.
I≤500m
a.s.l.
II≤300m
a.s.l.
III≤950m
a.s.l.
kNm
S-90PCN-3PS 50 0,671 0,456 0,403 0,252 14,0
S-100PCN-3PS 50 0,644 0,431 0,379 0,234 14,0
S-110PCN-3PS 50 0,618 0,409 0,358 0,216 14,0

Downloadable:
Ikony- pdf STEEL, ROUND SECTION, STRAIGHT, PCN-3PS, LE-E CATEGORY Catalog page