Technical data | |||||||
---|---|---|---|---|---|---|---|
TYPE
|
H
|
tbl
|
Ød/DE
|
Z
|
L
|
m
|
a x a x h TYPE
|
m
|
mm
|
mm/m
|
mm/m
|
mm
|
kg
|
m
|
|
S-90PCN-3PS
|
9,0
|
3,0
|
60/198
|
12,5
|
100
|
97
|
0,3 x 0,3 x 1,5
F150/200-PS |
S-100PCN-3PS
|
10,0
|
3,0
|
60/198
|
12,5
|
100
|
102
|
0,3 x 0,3 x 1,5
F150/200-PS |
S-110PCN-3PS
|
11,0
|
3,0
|
60/198
|
12,5
|
100
|
107
|
0,3 x 0,3 x 1,5
F150/200-PS |
Ød – other mounting diameters should be specified in the inquiry or order.
Passive safety classification according to PN-EN 12767:2019: 100LE-E-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100LE1;)
Strength data
|
||||||
TYPE
|
Weight of iluminaires
|
Wind Zone, PN EN 1991-1-4
Permissible surface of luminaires [m2] |
MF
|
|||
kg
|
I≤300m
a.s.l. |
I≤500m
a.s.l. |
II≤300m
a.s.l. |
III≤950m
a.s.l. |
kNm | |
S-90PCN-3PS | 50 | 0,671 | 0,456 | 0,403 | 0,252 | 14,0 |
S-100PCN-3PS | 50 | 0,644 | 0,431 | 0,379 | 0,234 | 14,0 |
S-110PCN-3PS | 50 | 0,618 | 0,409 | 0,358 | 0,216 | 14,0 |
Downloadable:
STEEL, ROUND SECTION, STRAIGHT, PCN-3PS, LE-E CATEGORY – Catalog page