Technical Data | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
TYPE
|
SHANK TYPE |
W
|
H
|
H2
|
R(max)
|
Ød/DE
|
Z
|
m*
|
a x h
TYPE |
|
m
|
m
|
m
|
m
|
mm
|
mm/m
|
kg
|
m
|
|||
S-50C-3PS-2w |
S-40PC-3PS-2w
|
1,0
|
5 |
1,0
|
0,65
|
60/121
|
12,5
|
42
|
0,43×1,2
F120PS-HE F120PS-LE |
|
1,5
|
44
|
|||||||||
2,0
|
46
|
|||||||||
2,5
|
48
|
|||||||||
S-60C-3PS-2w |
S-50PC-3PS-2w
|
1,0
|
6
|
1,0
|
0,65
|
60/136
|
12,5
|
52
|
0,43×1,2
F120PS-HE F120PS-LE |
|
1,5
|
54
|
|||||||||
2,0
|
56
|
|||||||||
2,5
|
58
|
|||||||||
S-70C-3PS-2w |
S-60PC-3PS-2w
|
1,0
|
7
|
1,0
|
0,65
|
60/149
|
12,5
|
62
|
0,43×1,2
F120PS-HE F120PS-LE |
|
1,5
|
64
|
|||||||||
2,0
|
66
|
|||||||||
2,5
|
68
|
|||||||||
S-80C-3PS-2w |
S-70PC-3PS-2w
|
1,0
|
8
|
1,0
|
0,65
|
60/161
|
12,5
|
73
|
0,43×1,2
F120PS-HE F120PS-LE |
|
1,5
|
75
|
|||||||||
2,0
|
77
|
|||||||||
2,5
|
79
|
|||||||||
S-90C-3PS-2w |
S-80PC-3PS-2w
|
1,0
|
9
|
1,0
|
0,65
|
60/174
|
12,5
|
85
|
0,43×1,5
F150PS-HE F150PS-LE |
|
1,5
|
87
|
|||||||||
2,0
|
89
|
|||||||||
2,5
|
91
|
|||||||||
S-100C-3PS-2w |
S-90PC-3PS-2w
|
1,0
|
10
|
1,0
|
0,65
|
60/186
|
12,5
|
99
|
0,43×1,5
F150PS-HE F150PS-LE |
|
1,5
|
101
|
|||||||||
2,0
|
103
|
|||||||||
2,5
|
105
|
|||||||||
S-110C-3PS-2w |
S-100PC-3PS-2w
|
1,0
|
11
|
1,0
|
0,65
|
60/199
|
12,5
|
113
|
0,43×1,5
F150PS-HE F150PS-LE |
|
1,5
|
115
|
|||||||||
2,0
|
117
|
|||||||||
2,5
|
119
|
|||||||||
S-120C-3PS-2w |
S-110PC-3PS-2w
|
1,0
|
12 |
1,0
|
0,65
|
60/210
|
12,5
|
127
|
0,43×1,5
F150PS-HE F150PS-LE |
|
1,5
|
129
|
|||||||||
2,0
|
131
|
|||||||||
2,5
|
133
|
Note: The height of the bracket – 1 m. Post with type ST-Y bracket shown. Type ST bracket is compatible with this post type.
* – Data for single arm brackets,
Ød, α° – other assembly diameters and inclination angles type should be specified in the inquiry or order.
For configuration of the C-3PS-2w pole integrated with the F120PS-HE or F150PS-HE foundation –
Passive safety classification according to PN-EN 12767:2019: 100HE-C-S-SE-SD-0;
70HE-C-S-SE-SD-0; 50HE-C-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100HE3; 70HE3; 50HE3).
For configuration of the C-3PS-2w pole integrated with the F120PS-LE or F150PS-LE foundation –
Passive safety classification according to PN-EN 12767:2019: 100LE-C-S-SE-SD-0;
70LE-C-S-SE-SD-0; 50LE-C-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100LE3; 70LE3; 50LE3).
Strength data | |||||||
---|---|---|---|---|---|---|---|
TYPE
|
W
|
Weight of iluminaires
|
Wind Zone, PN EN 1991-1-4
Permissible surface of luminaires [m2] |
MF
|
|||
m
|
kg
|
I≤ 300m a.s.l. |
I≤ 500m a.s.l. |
II≤ 300m a.s.l. |
III≤ 950m a.s.l. |
kNm | |
Single arm bracket | |||||||
S-50C-3PS-2w
|
2,0
|
14
|
0,139
|
0,080
|
0,065
|
0,019
|
4,1
|
S-60C-3PS-2w
|
2,0
|
14
|
0,234
|
0,146
|
0,124
|
0,057
|
5,5
|
S-70C-3PS-2w
|
2,0
|
14
|
0,240
|
0,143
|
0,119
|
0,047
|
7,2
|
S-80C-3PS-2w
|
2,0
|
14
|
0,286
|
0,171
|
0,143
|
0,060
|
8,7
|
S-90C-3PS-2w
|
2,0
|
14
|
0,319
|
0,190
|
0,158
|
0,066
|
10,4
|
S-100C-3PS-2w
|
2,0
|
14
|
0,342
|
0,202
|
0,167
|
0,068
|
12,3
|
S–110C-3PS-2w
|
2,0
|
14
|
0,358
|
0,208
|
0,171
|
0,067
|
14,2
|
S-120C-3PS-2w
|
2,0
|
14
|
0,356
|
0,202
|
0,164
|
0,058
|
16,1
|
Two arm bracket | |||||||
S-50C-3PS-2w
|
2,0 |
14
|
0,266
|
0,150
|
0,120
|
0,030
|
4,1
|
S-60C-3PS-2w
|
2,0
|
14
|
0,448
|
0,276
|
0,232
|
0,102
|
5,5
|
S–70C-3PS-2w
|
2,0
|
14
|
0,456
|
0,268
|
0,220
|
0,052
|
7,2
|
S-80C-3PS-2w
|
2,0
|
14
|
0,494
|
0,260
|
0,202
|
0,032
|
8,7
|
S-90C-3PS-2w
|
2,0
|
14
|
0,468
|
0,234
|
0,176
|
–
|
10,4
|
S-100C-3PS-2w
|
2,0
|
14
|
0,438
|
0,210
|
0,152
|
–
|
12,3
|
S-110C-3PS-2w
|
2,0
|
14
|
0,410
|
0,184
|
0,130
|
–
|
14,2
|
S-120C-3PS-2w
|
2,0
|
14
|
0,372
|
0,152
|
0,098
|
–
|
16,1
|
Downloadable:
STEEL, ROUND SECTION, WITH ARM, LASER WELDED C-3PS-2w, HE-C and LE-C CATEGORY – Catalog page