Technical data | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
TYPE
|
H
|
Ød/DE
|
Z
|
L
|
m
|
a x h
TYPE |
||||
m
|
mm/m
|
mm
|
mm
|
kg
|
m
|
|||||
S-40PC-4/Ø70-PS
|
4,0
|
70/121
|
12,5
|
200
|
45
|
0,43 x 1,2
F120PS-NE |
||||
S-50PC-4/Ø70-PS
|
5,0
|
70/136
|
12,5
|
200
|
58
|
0,43 x 1,2
F120PS-NE |
||||
S-60PC-4/Ø70-PS
|
6,0
|
70/149
|
12,5
|
200
|
72
|
0,43 x 1,2
F120PS-NE |
||||
S-70PC-4/Ø70-PS
|
7,0
|
70/161
|
12,5
|
200
|
86
|
0,43 x 1,2
F150PS-NE |
||||
S-80PC-4/Ø70-PS
|
8,0
|
70/174
|
12,5
|
200
|
102
|
0,43 x 1,5
F150PS-NE |
||||
S-90PC-4/Ø70-PS
|
9,0
|
70/186
|
12,5
|
200
|
120
|
0,43 x 1,5
F150PS-NE |
||||
S-100PC-4/Ø70-PS
|
10,0
|
70/199
|
12,5
|
200
|
138
|
0,43 x 1,5
F150PS-NE |
Ød – other mounting diameters should be specified in the inquiry or order.
Passive safety classification according to PN-EN 12767:2019: 100NE-B-S-SE-SD-0; 70NE-B-S-SE-SD-0; 50HE-B-S-SE-SD-0;
(Passive safety classification according to PN-EN 12767:2007: 100NE3; 70NE3; 50NE3;)
Strength data
|
||||||
TYPE
|
Weight of iluminaires
|
Wind Zone, PN EN 1991-1-4
Permissible surface of luminaires [m2] |
MF
|
|||
kg
|
I≤300 m n.p.m.
|
I≤500 m n.p.m.
|
II≤300 m n.p.m.
|
III≤950 m n.p.m.
|
kNm | |
S-40PC-4/Ø70-PS | 60 | 1,773 | 1,339 | 1,227 | 0,891 | 5,6 |
S-50PC-4/Ø70-PS | 60 | 1,817 | 1,365 | 1,250 | 0,903 | 8,1 |
S-60PC-4/Ø70-PS | 60 | 1,734 | 1,295 | 1,183 | 0,849 | 10,3 |
S-70PC-4/Ø70-PS | 60 | 1,594 | 1,179 | 1,076 | 0,768 | 12,3 |
S-80PC-4/Ø70-PS | 60 | 1,537 | 1,132 | 1,032 | 0,733 | 14,8 |
S-90PC-4/Ø70-PS | 60 | 1,500 | 1,103 | 1,003 | 0,711 | 17,6 |
S-100PC-4/Ø70-PS | 60 | 1,220 | 0,879 | 0,792 | 0,549 | 18,0 |
Downloadable: